<LOGO>
FM Transmitter Measurement Report
Created: 2023-02-02 08-07-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 4/5, 42 dBuV INTER
Pilot RDS Phase Difference
7.3 kHz 2.7 kHz 53 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 12 kHz 11446 0,7514
Modulation Power
Limit Measuring Tolerance
9,0 dBr 0,0 dBr
MIN AVE MAX % above 9,0 dBr
1,5 dBr 2,54 dBr 4,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 8:07, 2.02.2023
RT
"LE JOURNAL DE 8H - JOURNAL 08H00 DU JEUDI 02 FEVRIER 2023 "
AF EON
87.8, 88.1, 92.6, 93.0, 93.2, 93.8, 94.6, 94.9, 95.0, 95.1, 96.3, 96.5, 96.8, 99.2, 99.4, 99.5, 99.6, 99.9, 100.2, 100.7, 101.9 MHz F206, F203, F208, F222
FM Scope Station: 100.20 MHz, signal: 4/5 (42 dBuV) Max at: 12 kHz MIN: 11 kHz % above 75 kHz: 0,7514 Acquired: 2023/02/02 8:06:36 Total samples: 11446 Equivalent time: 0:09:32 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 4,3 dBr MIN: 1,5 dBr AVE: 2,54 dBr % above 9,0 dBr: 0,0 Last value: 2,2 dBr (2023/02/02 8:06:34) Station: 100.20 MHz, signal: 5/5 (42 dBuV) 07:54 07:56 07:58 08:00 08:02 08:04 08:06 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality